Horizontal Single Chamber Vacuum High Pressure Gas Quenching Furnace
Sources: Author:admin Release time:2021-02-04 15:00
Horizontal Single Chamber Vacuum High Pressure Gas Quenching Furnace
Description:
High pressure gas quenching furnace applied for gas quenching of material like tool steel,die steel,high speed steel,etc.It has no special dimension and shape requires for the components.The components feature little deformation and good cooling effect.
Technical Features:
The furnace is horizontal,single chamber,bottom loading structure.Furnace door open type can be customized design.
Excellent temperature uniformity realized by octagon-shaped furnace hearth.
For different cooling speed requirements,it can use single heat exchanger furnace hearth cooling or dual and muti-stage heat exchanger furnace hearth cooling.
For different components,horizontal single chamber gas quenching furnace is optional to use backside gas inlet quenching circulation system or front side gas inlet quenching circulation system.
Unique two-stage heat exchanger is adopted,so the heat exchanger area is twice than before.
?
Optional configuration of High Pressure Gas?Quenching Furnace:
1.Vacuum degree:high vacuum/medium vacuum
2.PLC:OMRON/Siemens/Mitsubishi
3.Temperature controller:SHIMADEN/EUROTHERM/Honeywell
4.Thermocouple:style,K type.N type
5.Record:Paperless recorder/paper recorder
6.HMI:Simulation screen/Touch screen
7.Electric components:High-quality domestic brand/Schneider/Siemens
8.Furnace door:On-line/off-line,vertical up and down,rotation
9.Gas quenching type:360°nozzle gas inject cooling/external heat
10.Furnace hearth:Graphite heating elements and graphite felt heat insulation/Molybdenum element and metal heat insulation
11.Vacuum pump and gauge:Foreign brand/high-quality Chinese brand
Specification of High Pressure Gas?Quenching Furnace
Spec\Model |
HVGQ-334S |
HVGQ-446S |
HVGQ-557S |
HVGQ-669S |
HVGQ-7711S |
HVGQ-8812S |
HVGQ-9915S |
Effective hot zone size W*H*L(mm) |
300*300*400 |
400*400*600 |
500*500*700 |
600*600*900 |
700*700*1100 |
800*800*1200 |
900*900*1500 |
Load Capacity(kg) |
75 |
250 |
400 |
600 |
1000 |
1200 |
1500 |
Heating Power(kw) |
48 |
75 |
90 |
150 |
270 |
360 |
480 |
Max.Temperature(℃) |
1150 |
1150 |
1150 |
1150 |
1150 |
1150 |
1150 |
1350 |
1350 |
1350 |
1350 |
1350 |
1350 |
1350 |
|
Temperature Uniformity(℃) |
±5 |
±5 |
±5 |
±5 |
±5 |
±5 |
±5 |
Vacuum degree(Pa) |
4*10-1 |
4*10-1 |
4*10-1 |
4*10-1 |
4*10-1 |
4*10-1 |
4*10-1 |
4*10-3/6*10-4 |
4*10-3/6*10-4 |
4*10-3/6*10-4 |
4*10-3/6*10-4 |
4*10-3/6*10-4 |
4*10-3/6*10-4 |
4*10-3/6*10-4 |
|
Pressure Increase Rate(Pa/h) |
≤0.26 |
≤0.26 |
≤0.26 |
≤0.26 |
≤0.26 |
≤0.26 |
≤0.26 |
≤0.65 |
≤0.65 |
≤0.65 |
≤0.65 |
≤0.65 |
≤0.65 |
≤0.65 |
|
Gas quenching pressure(bar) |
6/10/15/20 |
6/10/15/20 |
6/10/15/20 |
6/10/15/20 |
6/10/15/20 |
6/10/15/20 |
6/10/15/20 |
Cooling gas(100.00%) |
N2/Ar/He |
N2/Ar/He |
N2/Ar/He |
N2/Ar/He |
N2/Ar/He |
N2/Ar/He |
N2/Ar/He |
?